Hot-wire anemometry and cylinder wake
Experimental aerodynamic measurements using hot-wire anemometry, including full sensor characterization, calibration, and wake flow analysis of a circular cylinder.
Sensor characterisation and calibration
The probe's dynamic response was determined through impulse analysis, obtaining a cutoff frequency of 10 kHz, ensuring suitability for resolving turbulent fluctuations. The hot-wire was calibrated using King's Law over a velocity range of 3–20 m/s, achieving excellent fit accuracy (R² = 0.9998), enabling reliable conversion of voltage signals into instantaneous velocity.
/assets/img/projects/hotwire-calibration.pngWake analysis
The wake of a circular cylinder (D = 32 mm) was then analysed using high-frequency sampling, computing power spectral densities to identify vortex shedding frequencies and their dependence on freestream velocity.
/assets/img/projects/hotwire-psd.pngTurbulence statistics revealed significant velocity deficits and high turbulence intensity (27–32%) in the wake. Time-frequency analysis via STFT was additionally implemented to track the shedding frequency evolution, confirming temporal stability and agreement with Strouhal-based theoretical predictions.